Product Description
- Constant voltage design
- Universal AC input / Full range
- Withstand 300V AC surge input for 5 seconds
- Protections:Short circuit / Over load / Over voltage
- Cooling by free air convection
- Fully encapsulated with IP67 level (Note.8)
- Fully isolated plastic case
- Class 2 power unit
- Suitable for LED lighting and moving sign applications (Note.7)
- 100% full load burn in test
- Low cost, high reliabitlity
- Mean Well LPV-100-36 LED Driver x 1
Details
Features:
MODEL |
LPV-100-5 |
LPV-100-12 |
LPV-100-15 |
LPV-100-24 |
LPV-100-36 |
LPV-100-48 |
|||||||
OUTPUT |
DC VOLTAGE |
5V |
12V |
15V |
24V |
36V |
48V |
||||||
CONSTANT CURRENT |
|
|
|
|
|
|
|||||||
CURRENT RANGE |
0 ~ 12A |
0 ~ 8.5A |
0 ~ 6.7A |
0 ~ 4.2A |
0 ~ 2.8A |
0 ~ 2.1A |
|||||||
RATED CURRENT |
12A |
8.5A |
6.7A |
4.2A |
2.8A |
2.1A |
|||||||
RATED POWER |
60W |
102W |
100.5W |
100.8W |
100.8W |
100.8W |
|||||||
RIPPLE & NOISE |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
|||||||
VOLTAGE |
|
|
|
|
|
|
|||||||
|
|||||||||||||
VOLTAGE |
|
||||||||||||
VOLTAGE |
8.0% |
5.0% |
|||||||||||
LINE REGULATION |
1.0% |
||||||||||||
LOAD REGULATION |
6.0% |
2.0% |
|||||||||||
SETUP, RISE |
2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC |
||||||||||||
HOLD UP TIME |
50ms/230VAC 16ms/115VAC at full load |
||||||||||||
INPUT |
VOLTAGE |
90 ~ 264VAC 127 ~ 370VDC |
|||||||||||
FREQUENCY RANGE |
47 ~ 63Hz |
||||||||||||
POWER FACTOR |
|
||||||||||||
EFFICIENCY(Typ.) |
78% |
84% |
85% |
86% |
87% |
88% |
|||||||
AC CURRENT(Typ.) |
2.2A/115VAC 1.2A/230VAC |
||||||||||||
INRUSH |
COLD START 30A/115VAC 60A/230VAC |
||||||||||||
LEAKAGE CURRENT |
0.25mA / 240VAC |
||||||||||||
PROTECTION |
OVER CURRENT |
110 ~ 150% rated output power |
|||||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||||||||||
SHORT CIRCUIT |
|
||||||||||||
OVER VOLTAGE |
5.75 ~ 6.75V |
13.8 ~ 16.2V |
17.25 ~ 20.25V |
27.6 ~ 32.4V |
41.4 ~ 48.6V |
55.2 ~ 64.8V |
|||||||
Protection type : Shut down o/p voltage, re-power on to recover |
|||||||||||||
FUNCTION |
|
||||||||||||
ENVIRONMENT |
WORKING TEMP. |
-25 ~ +70 (Refer to output load derating curve) |
|||||||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||||||||||
STORAGE TEMP., |
-40 ~ +80 , 10 ~ 95% RH |
||||||||||||
TEMP. COEFFICIENT |
0.03%/ (0 ~ 50 ) |
||||||||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
||||||||||||
SAFETY |
SAFETY STANDARDS |
Design refer to TUV EN60950-1, EN61347-2-13, IP67 approved |
|||||||||||
WITHSTAND |
I/P-O/P:3KVAC |
||||||||||||
ISOLATION |
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH |
||||||||||||
EMI CONDUCTION |
Compliance to EN55022 (CISPR22) Class B |
||||||||||||
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
||||||||||||
EMS IMMUNITY |
|
||||||||||||
OTHERS |
MTBF |
Khrs min. MIL-HDBK-217F (25 ) |
|||||||||||
DIMENSION |
190*51*35mm (L*W*H) |
||||||||||||
PACKING |
Kg |
Additional Information
Additional Information
UPC | No |
---|